Introduction
For commercial and industrial facilities, a reliable electricity supply is essential to daily operations. However, rising fuel costs, unstable grid conditions, and growing electricity demand are creating new challenges for businesses worldwide.
Factories, agricultural facilities, mining operations, and remote industrial sites often depend on a combination of utility electricity and diesel generators. While diesel generators can provide backup power, continuous fuel consumption and maintenance requirements can increase operating costs.
Solar photovoltaic (PV) systems offer an alternative source of electricity, but solar generation varies throughout the day and depends on weather conditions.
Integrating solar PV, battery energy storage systems (BESS), and diesel generators provides a more flexible approach to power management.
The RENAC RENA5000 Energy Storage Solution is designed to support this integration through a coordinated commercial and industrial microgrid architecture.
By combining solar generation, intelligent battery storage, diesel generator coordination, and energy management technology, RENA5000 helps businesses improve energy flexibility, strengthen power supply reliability, and make better use of renewable electricity.
Why Combine Solar PV, Battery Storage and Diesel Generators?
A conventional diesel-powered facility relies on fuel consumption to produce electricity whenever grid power is unavailable.
Although diesel generators provide dispatchable power, operating them for extended periods can create several challenges:
-
High fuel consumption and exposure to fuel price fluctuations
-
Regular maintenance requirements
-
Noise and exhaust emissions
-
Inefficient operation under certain low-load conditions
-
Dependence on fuel transportation and availability
Solar PV generation can reduce the amount of electricity that must be supplied by the generator during daylight hours.
However, solar panels cannot continuously meet electricity demand when sunlight is insufficient.
Battery energy storage addresses this limitation by storing available electricity and discharging it when needed.
A hybrid PV + BESS + DG microgrid combines three complementary energy sources:
Solar PV: Generates renewable electricity during daylight hours.
Battery Energy Storage: Stores electricity and supplies power according to demand.
Diesel Generator: Provides an additional dispatchable source of electricity when required.
An intelligent Energy Management System (EMS) coordinates these resources according to available generation, battery state of charge, facility demand, and operating priorities.
This integrated approach can reduce unnecessary generator operation while maintaining flexibility in power supply.
How Does a PV + BESS + DG Microgrid Work?
The operating strategy of a solar-storage-diesel microgrid changes throughout the day.
A well-designed system must balance renewable energy availability, battery storage capacity, and electricity consumption.
Scenario 1: Daytime Solar Generation
During periods of strong sunlight, solar PV generation can supply electricity directly to connected loads.
When solar production exceeds immediate electricity demand, surplus energy can be used to charge the battery system, subject to operating limits.
This allows businesses to store renewable electricity for later use.
Where the solar and battery systems can meet the required load, diesel generator operation may be reduced or avoided.
For commercial facilities, this operating strategy can improve solar energy utilization and reduce dependence on fuel-based electricity generation.
Scenario 2: Evening and Low-Solar Conditions
As sunlight decreases, solar generation may no longer meet the facility's electricity demand.
The battery energy storage system can discharge previously stored electricity to support connected loads.
An intelligent EMS manages battery discharge according to operating requirements, available energy, and battery protection limits.
This enables businesses to extend the use of solar-generated electricity beyond daylight hours.
The actual operating duration depends on battery capacity, connected loads, available solar energy, and the required battery reserve.
Scenario 3: Low Battery Capacity
When solar generation is insufficient and the battery reaches a configured minimum state of charge, additional power may be required.
In a properly configured hybrid microgrid, the EMS can coordinate operation with a compatible diesel generator.
The generator may supply facility loads and, where the system design permits, contribute to battery charging.
This helps maintain electricity availability when renewable generation and stored energy cannot meet demand.
Generator start and stop conditions should be configured according to equipment compatibility, operating requirements, and the site's electrical design.
Scenario 4: Utility Grid Interruption
For grid-connected facilities, a sudden power outage can disrupt important equipment and business operations.
A hybrid battery storage system equipped with suitable switching and microgrid control equipment can support the transition from grid-connected operation to an off-grid configuration.
During this transition, the energy storage system may provide power to designated loads while the microgrid controller coordinates the available energy sources.
This is particularly valuable for facilities where electricity interruptions can affect productivity or operational safety.
RENAC RENA5000: An Integrated Hybrid Energy Storage Solution
RENAC Power Technology Co., Ltd. developed the RENA5000 C&I Energy Storage Solution to support commercial and industrial applications requiring flexible energy management.
The system combines standardized modular design with coordinated control of renewable generation, battery storage, and additional power sources.
RENA5000 supports multiple operating configurations, including:
-
Grid-connected solar and battery storage
-
AC-coupled PV plant retrofits
-
DC-coupled solar-plus-storage projects
-
Off-grid battery energy storage
-
PV + BESS + diesel generator microgrids
-
Grid-connected and off-grid backup power applications
The solution uses RENAC's integrated 5S architecture, coordinating power conversion, battery storage, photovoltaic control, switching equipment, and energy management.
This architecture is designed to simplify system integration and enable different energy sources to operate within a coordinated electrical system.
Key Technologies Supporting Solar-Storage-Diesel Integration
1. ESS-261: Commercial Battery Energy Storage
The RENAC ESS-261 is an all-in-one commercial and industrial battery energy storage system featuring:
Rated Power: 125kW
Nominal Energy Capacity: 261kWh
Battery Technology: Lithium Iron Phosphate (LFP)
The system adopts a standardized modular architecture and supports compatible parallel configurations for capacity expansion.
Within a hybrid microgrid, ESS-261 stores electricity and supplies power according to the energy management strategy.
Its operating capabilities support solar self-consumption, peak shaving, and flexible electricity management.
2. STS-400: Intelligent Microgrid Control
The RENAC STS-400 is a microgrid control system designed for commercial and industrial energy storage applications.
It supports coordinated operation between the utility grid, battery energy storage, and compatible diesel generators.
The STS-400 integrates multiple functions, including:
-
Static transfer switching
-
Power distribution
-
Electrical circuit protection
-
Surge protection
-
Smart metering
-
Grid-connected and off-grid operation
The STS-400-G/D configuration supports diesel generator integration with a maximum DG input power rating of 400kW.
In supported configurations, switching between grid-connected and off-grid operation can occur in less than 20 milliseconds.
Its integrated architecture also reduces the need for separate power distribution equipment, helping simplify installation and system wiring.
For hybrid microgrid applications, STS-400 provides an important connection between energy storage, generator operation, and electrical loads.
3. PVS-125K: Flexible Solar PV Integration
The RENAC PVS-125K is a photovoltaic controller designed for DC-coupled solar and battery energy storage applications.
With a rated output power of 125kW and 10 independent MPPT channels, it supports flexible solar PV input configurations.
The controller allows solar generation to be integrated with compatible RENA5000 energy storage systems through a DC-coupled architecture.
This configuration is particularly relevant to new solar-plus-storage projects where coordinated PV and battery operation is required.
4. EMS: Coordinated Energy Management
The Energy Management System plays a central role in hybrid microgrid operation.
Within a suitable RENA5000 configuration, the EMS coordinates electricity generation, storage, and consumption.
Its operating strategy can be designed around several objectives:
Prioritizing Renewable Energy
Using available solar electricity to support facility loads and battery charging.
Managing Battery Charging and Discharging
Controlling battery operation according to energy availability and electricity demand.
Coordinating Diesel Generator Operation
Working with compatible generator equipment to support additional power supply when needed.
Supporting Grid and Off-Grid Operation
Managing energy storage behavior under different electrical operating conditions.
Through coordinated control, businesses can manage multiple energy sources within one energy storage architecture.
VSG Grid-Forming Technology: Supporting Off-Grid Power Supply
One of the important technologies within the RENAC RENA5000 solution is Virtual Synchronous Generator (VSG) control.
In conventional grid-connected operation, electrical equipment generally operates with reference to the utility grid.
However, in an isolated microgrid, the system must establish and maintain suitable voltage and frequency conditions.
VSG grid-forming technology enables compatible power conversion equipment to provide grid-forming functions during off-grid operation.
This capability helps support the coordinated operation of battery storage and other power sources.
For PV + BESS + DG applications, grid-forming control is particularly important because the system may need to operate independently of the utility grid.
RENAC RENA5000 combines VSG technology with microgrid control to support energy storage and generator coordination.
The final operating performance depends on system configuration, equipment ratings, generator compatibility, and load conditions.
AC Coupling and DC Coupling for Different Projects
RENA5000 supports both AC and DC coupling, allowing businesses to select a suitable architecture based on project requirements.
AC Coupling: Upgrading Existing Solar PV Systems
For facilities with existing photovoltaic installations, AC coupling can allow the battery storage system to connect through the AC electrical network.
Compatible existing PV inverters can remain in operation.
This provides several practical advantages:
-
Retaining existing solar generation equipment
-
Reducing unnecessary equipment replacement
-
Simplifying solar PV plant retrofits
-
Adding battery storage without extensively modifying the original PV system
AC coupling is especially relevant to existing commercial solar plants seeking additional storage and energy management capabilities.
DC Coupling: Integrating Solar and Storage in New Projects
For new renewable energy installations, DC coupling allows photovoltaic generation to connect through the PVS-125K controller.
This supports coordinated solar generation and battery storage within a common system architecture.
DC coupling can be considered for new commercial and industrial microgrids where PV generation and storage are planned together.
The appropriate coupling method depends on system design, site requirements, available equipment, and operational objectives.
Benefits of RENAC RENA5000 for Commercial and Industrial Users
Reduced Dependence on Diesel Generation
In hybrid microgrids, solar electricity and stored battery energy can supply part of a facility's electricity demand.
This may reduce diesel generator operating hours when sufficient renewable energy and battery capacity are available.
Potential fuel savings depend on electricity consumption, solar production, generator efficiency, and the selected operating strategy.
Improved Power Supply Flexibility
Battery storage provides an additional source of electricity when solar generation decreases or grid conditions change.
With suitable switching and control equipment, RENA5000 supports flexible grid-connected and off-grid operation.
Better Renewable Energy Utilization
Surplus solar electricity can be stored and discharged when required.
This allows facilities to use more of their renewable generation instead of relying entirely on immediate solar consumption.
Simplified System Integration
RENA5000 uses standardized system components and coordinated control.
This can reduce integration complexity compared with projects requiring extensive customization between equipment from multiple suppliers.
Flexible Capacity Planning
The modular architecture supports compatible parallel operation and allows project developers to plan different power and storage capacities.
The final configuration should be selected according to electrical demand, operating conditions, and project objectives.
Where Can Solar-Storage-Diesel Microgrids Be Used?
Manufacturing Facilities
Factories with unstable electricity supplies may experience production interruptions when grid power is unavailable.
A hybrid energy storage system can combine solar generation, battery storage, and backup generation to support essential electricity demand.
Agricultural Facilities
Farms may require electricity for irrigation, refrigeration, processing equipment, and other operations.
Solar-plus-storage systems can help reduce reliance on conventional electricity sources, particularly in locations with limited grid access.
Mining Operations
Remote mining sites often have significant electricity demand and may depend on diesel generators.
Integrating solar generation and battery storage can provide additional flexibility in electricity supply and potentially reduce fuel consumption.
Islands and Remote Communities
Locations without stable utility grid infrastructure may require independent power systems.
Hybrid PV + BESS + DG configurations can combine renewable electricity, stored energy, and dispatchable generation to meet different load conditions.
Commercial Facilities Requiring Backup Power
Hotels, logistics facilities, and other commercial buildings may require backup power for selected equipment.
A properly designed battery energy storage and microgrid control system can improve power supply flexibility and support critical-load planning.
RENA5000 for Island and Remote Energy Applications
In 2025, RENAC presented its RENA5000 hybrid solar-storage-diesel microgrid solution at an international energy exhibition in the Philippines.
The solution was introduced for applications where electricity reliability and energy independence are important, including island and remote energy systems.
The product configurations presented included:
| PV Capacity | ESS Power | Battery Capacity |
|---|---|---|
| 125kWp | 125kW | 261kWh |
| 250kWp | 250kW | 522kWh |
| 375kWp | 375kW | 783kWh |
| 500kWp | 500kW | 1,044kWh |
These configurations illustrate the modular approach used in the RENA5000 solution.
The system was presented with VSG grid-forming technology, flexible multi-energy coordination, and support for off-grid operating conditions.
For island facilities and remote industrial users, such architectures provide an option for combining renewable generation with battery storage and backup power sources.
The configurations above represent product solutions presented by RENAC, rather than confirmed specifications of a particular installed project.
How to Plan a Commercial Hybrid Microgrid
Before selecting a PV + BESS + DG solution, businesses should evaluate several factors.
Electricity Demand
Understand the facility's daily electricity consumption, peak power demand, and important electrical loads.
Solar Generation Potential
Assess available installation space, solar conditions, and expected photovoltaic electricity production.
Battery Capacity
Determine the required battery storage capacity based on operating objectives, load demand, and desired backup duration.
Diesel Generator Compatibility
Review generator power ratings, operating characteristics, communication interfaces, and system integration requirements.
Grid Connection Requirements
Determine whether the facility will operate primarily on-grid, off-grid, or in a combination of both modes.
Energy Management Strategy
Define how solar generation, battery charging and discharging, and diesel generator operation should be prioritized.
A suitable system design should consider both energy performance and electrical safety.
Frequently Asked Questions
What is the RENAC RENA5000 Energy Storage Solution?
RENA5000 is a commercial and industrial energy storage solution developed by RENAC Power.
It supports solar PV integration, battery storage, intelligent energy management, and compatible hybrid microgrid configurations.
Can RENA5000 work with diesel generators?
Yes. RENA5000 supports solar-storage-diesel microgrid configurations with suitable equipment.
The STS-400-G/D microgrid control system is designed to support coordinated operation between the utility grid, energy storage, and compatible diesel generators.
Can battery storage reduce diesel generator operating hours?
Yes, under suitable operating conditions.
When solar generation and stored battery energy can meet facility demand, generator operating hours may be reduced.
The actual reduction depends on the site's electricity requirements and system configuration.
Does RENA5000 support off-grid operation?
Yes. RENA5000 supports off-grid applications through compatible power conversion, energy management, and microgrid control equipment.
VSG grid-forming technology supports operation when a utility grid reference is unavailable.
What is the benefit of using an STS in a hybrid microgrid?
An STS supports switching between electrical operating modes and helps coordinate power supply configurations.
In suitable RENA5000 installations, compatible STS equipment supports switching between grid-connected and off-grid operation in less than 20 milliseconds.
Can RENA5000 support both AC and DC coupling?
Yes. RENA5000 supports AC coupling for compatible existing solar PV systems and DC coupling for new solar-plus-storage projects.
The appropriate configuration depends on the electrical design and project requirements.
Conclusion
For commercial and industrial facilities, managing electricity demand requires a balance between cost efficiency, renewable energy utilization, and reliable power supply.
Solar generation can provide renewable electricity, battery storage can improve energy flexibility, and diesel generators can supply additional power when required.
Integrating these resources through a coordinated microgrid architecture helps businesses respond to changing energy conditions.
The RENAC RENA5000 Energy Storage Solution supports this approach through its modular battery storage architecture, intelligent EMS, flexible AC/DC coupling, and compatible microgrid control technologies.
With components such as ESS-261, PVS-125K, and STS-400, RENA5000 provides a coordinated solution for commercial and industrial solar-storage-diesel applications.
For factories, agricultural facilities, mining operations, and remote commercial sites, this integration offers a practical approach to improving renewable energy utilization and power supply flexibility.
As businesses continue exploring more efficient and resilient energy infrastructure, integrated hybrid microgrid solutions such as RENA5000 provide additional options for long-term energy management.
Learn more about the RENAC RENA5000 Energy Storage Solution:
https://www.renacpower.com/
Renac Power Technology Co., Ltd.




